Choose it for
Maximum reserve, frequent backup use and clearer control of the active output.
DC power for your CPAP. Check your machine, cable and planned runtime below.
With humidifier and heated tube off. Actual runtime varies.
Free standard shipping to eligible U.S. addresses. U.S. stock ships within 1 business day.
With humidifier and heated tube off. Actual runtime varies.
A high-reserve CPAP battery with visible percentage control for repeat outages and longer backup plans.
Up to 100W USB-CCharge phones, tablets and compatible laptops.
A high-reserve CPAP battery for repeated outages, bedside backup and road-based trips. Plan for 3+ nights with humidifier and heated tube off. Actual runtime varies.
The percentage display makes it easier to compare what remains after a real night and decide when to recharge.
Four model-family DC cables are included. Confirm the machine, adapter voltage and cable before connecting.
Choose a documented route before the next outage or trip, then verify the source and connection sequence.
Pass-through charging can keep the CPAP connected while the battery recharges; test the complete setup before relying on it overnight.
At 297.6Wh, ES960 PRO is not designed for passenger-aircraft carry-on.
Planning ranges assume humidification and heated tubing are off and are not runtime guarantees. Actual runtime varies with the CPAP model, prescribed pressure, mask leak, room temperature, battery condition and comfort settings.
Keep prescribed therapy settings unchanged, confirm the cable and voltage, and run one complete overnight test before relying on the setup.
Road, RV and off-grid planning; capacity exceeds the usual 160Wh passenger-baggage limit.
The current model manual lists these contents. Confirm the exact machine and cable before use; additional cables or optional charging equipment may be sold separately. Camo models use their corresponding PRO manual.
Purchases from easylonger.com include a 5-year warranty. Purchases from other authorized platforms include 3 years and can be registered on our website to upgrade eligible coverage to 5 years. Free shipping is available to eligible U.S. addresses, and eligible orders may be returned in their original packaging within 30 days of receipt; approval and return-shipping terms apply.
Open the model-specific support workspace for setup videos, connection guidance and the current manual. If your CPAP is not listed, send the adapter label and machine model to support before ordering.
Why choose ES960 PRO
ES960 PRO adds a percentage display and expanded outputs to the long-life LiFePO4 platform. It is easier to plan when you can see what remains after each real night.
Check my CPAP
Maximum reserve, frequent backup use and clearer control of the active output.
Select the exact CPAP cable and voltage before using any of the additional outputs.
Other devices can share the platform, but the overnight reserve must be protected.
Tech specs
Review capacity, output, CPAP connection, travel and support details before you order.
Planning ranges assume humidification and heated tubing are off and are not runtime guarantees. Actual runtime varies with the CPAP model, prescribed pressure, mask leak, room temperature, battery condition and comfort settings.
Owner setups
Customer photos show the machine, cable route and bedside space together.


Complete the setup
Optional accessories for solar charging, travel and specific CPAP connections.
For all EASYLONGER CPAP batteries
110W foldable solar recharging. Confirm the battery input range, connector and expected conditions.
For ES960 series
Includes a basic storage bag; this padded organizer is an optional upgrade.
For Luna G3 only
A 24V cable for the named Luna G3 CPAP and BiPAP models. Confirm the machine and original adapter label.
For Transcend Micro only
A 19V cable for the named Transcend Micro models. Confirm the machine and original adapter label.
ES960 PRO has 297.6Wh of battery capacity for compatible CPAP equipment and everyday USB devices. Connect your CPAP using the cable and output voltage specified for its exact model.
USB-C output supports up to 100W for phones, tablets and compatible USB-C laptops. Check your device's charging requirements before connecting.
Keep the CPAP disconnected while selecting voltage. Confirm the exact machine and cable, then match the voltage printed on its original power adapter. If you select the wrong value, exit voltage mode and reset it as the battery manual directs before connecting the CPAP.
Yes. ES960 PRO supports pass-through charging with the charger and connections specified in its manual. The battery level can still fall if your equipment uses more power than the charger supplies. Keep the battery ventilated and test the complete setup before relying on it overnight.
Planning range: 3+ nights with humidifier and heated tube off. Actual runtime varies with your CPAP model, pressure, leakage, temperature and battery condition. Test the complete setup with your usual settings before relying on it away from home.
Match the complete CPAP model and adapter voltage in the compatibility guide. Connector shape alone is not enough.
Charge fully, verify voltage and cable, then run one complete night using the settings you plan to rely on.
Eligible purchases from easylonger.com include a 5-year warranty and direct product support. Eligible orders can be returned within 30 days of receipt; approval is required and shipping or handling fees may apply. Check the terms for your order below.
Connection guides for this battery. Match the machine shown to your own setup.
English PDF. Opens in a new tab.
Still need help with your ES960 PRO?
Email EASYLONGER support